1, electronic portable scale into the calibration status:
The first method: Press/Key, immediately press Tare, unit two keys, display 8888, then release two keys, display "Ten. 00kg", that is, to enter the calibration state.
The second method: Press and hold tare, unit two keys, and then on the battery boot, showing 8888 rear open two keys;

2, select the function: Show "ten. 00kg" After the tare to change the standard quantitative process, by 10.00 → 20.00 → 40.00 → 60.00 → 10.00 cycle. After selecting the range, press the unit key to confirm. Then displays an inner code value;

3, Calibration: Display inside code value, the vertical hanging hand scale when the unit key, calibrate 0 points, display "Calo", and then show the inner code value. Then add a full range of half the weight, and then press the unit key to confirm, display a full range of half the number, and then display a value. Thereafter increase the weight to full range, and then press the unit key to confirm, display full range, waiting to show pass after shutdown.

4, for example: the calibration of a 20kg portable said, should first enter the calibration state, showing the calibration status, showing the ten. After 00kg press the Tare key, display. 00kg, click the Unit key and display the value of the code. Hang up the portable said, press the unit key, calibrate 0 points, display "Calo", show the Inside code value, and then add a 10kg weight, click the unit key, display "ten. 00kg", display the value, then add a 10kg weight, that is, total 20kg weight, click the unit key, display "pass" after the automatic shutdown, calibration completed.